top of page

LoRaWAN Oxygen Sensor

SKU#

WSLRW-O2

Replaced by

Replaced SKU

WSLRW-O2 is the Wireless Ambient Oxygen Sensor, it utilizes a galvanic cell type oxygen sensor that provides a linear output voltage signal relative to the percent oxygen present in a particular atmosphere. The sensor features no position dependency, excellent chemical durability, and it is not influenced by CO. With Ultra-low Power design and smart firmware allow the sensor can last up to 10 years with 02 x AA-type battery (depends on configuration). The sensor will transmit data in kilo-meters distance to LoRaWAN gateway, any brand on the market. There are a lot of applications as environment monitoring for office, hospital, cleanroom, agriculture, food warehouse...

For Applications

Ambient Air Quality Monitor, Indoor Air Quality Monitor, Gas Analyzing, Warehouse Monitoring

LoRaWAN communication

LoRaWAN communication standard to allow sensor connect to any LoRaWAN Gateway on the market

Not affected by other gases

Virtually no influence from CO2, CO, H2S, NO, H2 (Version O2-02)

5-10 years battery

Ultra-low power sensing technology from Daviteq with Ultra-low power wireless technology allows the sensor can last up to 5-10 years with 02 x AA batteries

Not affected by temperature changes

Temperature compensation circuit included

Measuring range/ Max overload0∼25% O₂/ 30% O₂
Accuracy/ Resolution±0.25% O₂/ 0.01
Long term output drift< 5% of reading per year
Interference gases for version O2-01CO₂, not used in the environment with CO₂ > 25% (1% of CO₂ will increase 0.3% of O₂ output)
Interference gases for version O2-02Virtually no influence from CO₂, CO, H₂S, NO, H₂. Only influenced by NO₂ (1% NO₂ will increase 0.6% of O₂ output)
Working Pressure1013hPa ±20%
Working Temperature-10∼50℃ for O2-02 and -30∼50℃ for O2-01
Storage Temperature0∼20℃
Working Humidity0-99% RH non-condensation for O2-02 and 5∼95%, non-condensation for O2-01
Response time≤15s (Sensors should be used under conditions where the air exchange is greater than 200∼300ml/minute)
Life expectancy at 20℃ in normal airapprox. 3 years for O2-02 and 2 years for O2-01
COMMUNICATION
SF FactorsSF7∼SF12
AntennaInternal Antenna 2.0 dbi
Battery02 x AA size 1.5VDC, battery not included
RF Frequency and Power860∼930MHz, 14∼20dBm, configurable for zones: EU868, IN865, RU864, KR920, AS923, AU915, US915
ProtocolLoRaWAN, class A
Data sending modesInterval time and when alarm occurred
RF Module complies toETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD-T108 (Japan)
Vietnam Type ApprovalTBA soon
Working temperature-40∼60℃ (with AA L91 Energizer®)
Housing/ProtectionAluminum + Polycarbonate/ IP67
Dimension and Net weightH180xW73xD42, < 400g

Dimension

Application Notes

Only available for Logged-in member. Please log-in or register to access this information